Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Dent Mater ; 40(1): 80-89, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37919111

RESUMO

OBJECTIVES: To evaluate the effect of mono and multi-wave light-curing units (LCUs) on the Knoop hardness of resin-based composites (RBC) that use different photoinitiators. METHODS: Central incisor-shaped specimens 12 mm long, 9 mm wide, and 1.5 mm thick were made from 2 RBCs that use different photoinitiators: Tetric N-Ceram (Ivoclar Vivadent) - and Vittra APS (FGM), both A2E shade. They were light-cured with 4 different LCUs: two claimed to be multi-wave - VALO Grand (Ultradent) and Emitter Now Duo (Schuster); and two were monowave - Radii Xpert (SDI) and Elipar DeepCure-L (3 M Oral Care) using 2 different light exposure protocols: one 40 s exposure centered over the specimen; and two 20 s light exposures that delivered light from two positions to better cover the entire tooth. 16 groups with 10 specimens in each group were made. The Knoop hardness (KH, kg/mm2) was measured at the top and bottom of the specimen in the center and at the cervical, incisal, mesial, and distal peripheral regions. The active tip diameters (mm) and spectral radiant powers (mW/nm) of the LCUs were measured with and without the interposition of the RBC, as well as the radiant exposure beam profiles (J/cm²) delivered to the top of the RBCs. The data was analyzed using Three-way ANOVA and Tukey's tests (α = 0.05). RESULTS: The VALO Grand (1029 mW) emitted twice the power of the Radii Xpert (500 mW). The KH values of VI and TN resin composite specimens were significantly affected by the LCU used (p < .001), the measurement location (p < .001), and the surface of the specimen (p < .001). LCUs with wider tip diameters produced greater Knoop hardness values at the peripheries of the 12 mm of long, 9 mm wide specimens. In general, the VALO Grand produced the highest KH values, followed by Elipar DeepCure-L, then by Radii Xpert. The Emitter Now Duo LCU produced the lowest values. Exposing the veneers from two locations reduced the differences between the LCUs and the effect of the measurement location. Only the VALO Grand could fully cover the composite veneer with light when the two locations were used. SIGNIFICANCE: The light tip must cover the entire restoration to photocure the RBC beneath the light tip.


Assuntos
Luzes de Cura Dentária , Cura Luminosa de Adesivos Dentários , Dureza , Teste de Materiais , Resinas Compostas , Materiais Dentários , Polimerização
2.
J Appl Oral Sci ; 31: e20230241, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37909530

RESUMO

OBJECTIVE: The use of a fiber glass post (FGP) type and choice of FGP diameter to restore endodontically treated incisors without ferrule is controversial. This study evaluated survival rate and failure mode of severely compromised central incisors without ferrule rehabilitated using resin-based composite (RBC) with or without FGP with different diameters. METHODOLOGY: A total of 60 decoronated bovine incisors without a ferrule were endodontically treated and prepared for 1.4, 1.6, and 1.8 mm diameter FGPs (Whitepost System DC 0.5, Fit 0.4, and DCE 0.5; FGM). Half of the teeth received FGPs cemented using dual-cure resin cement (Allcem Core; FGM), the other half were filled using only bulk-fill RBC (OPUS Bulk Fill; FGM). The crowns were directly restored with RBC. The roots were embedded in polystyrene resin and the periodontal ligament was simulated with polyether impression material. Fatigue testing was conducted under 5 Hz cyclic loading at 30 degrees to the incisal edge, beginning at 50 N (5,000 cycles) as a warmup. After, the load was increased 100 N every 15,000 cycles until fracture occurred. All specimens were subjected to transillumination, micro-CT analysis, and digital radiography before and after fatigue testing. Fracture mode was classified according to severity and repair potential. Data were analyzed with Kaplan-Meier survival test and post hoc log-rank test (α=0.05) for pairwise comparisons. RESULTS: Using FGP significantly increased the number of cycles to failure, irrespective of FGP diameters (p=0.001). The FGP diameters had no statistically significant effect on cycles to failure or failure mode. CONCLUSION: Using FGP without ferrule improved survival rate of structurally severely compromised central incisors compared with rehabilitation without FGP. The diameter of the FGPs had no effect on the survival rate and failure mode.


Assuntos
Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Dente não Vital , Animais , Bovinos , Resinas Compostas , Coroas , Materiais Dentários , Vidro , Análise do Estresse Dentário , Falha de Restauração Dentária
3.
Dent Traumatol ; 39(4): 324-332, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36756994

RESUMO

BACKGROUND/AIM: Contamination of ethylene vinyl acetate (EVA) during mouthguard fabrication can cause delamination. The study evaluated the effects of different EVA surface treatments on the contact angle, laminate bond strength, and elongation capacity. MATERIALS AND METHODS: Specimens of two bonded EVA plates were prepared (n = 30). The Shore A hardness of standardized EVA plate specimens was measured before and after thermo-plasticization. The EVA plates were randomly allocated to one of five different surface treatment groups: no treatment (control); isopropyl alcohol, 100%; chloroform, 99.8%; self-cure acrylic resin monomer (methacrylate, ethylene glycol dimethacrylate, and chemical initiator-amine type); and ethyl alcohol, 70%. The maximum breaking force and elongation at the site of fracture were recorded using a universal testing machine. The contact angle surface was measured using ImageJ software. Scanning electron microscopy of the EVA surface was performed. The laminate bond strength was obtained by dividing the maximum breaking force by the bonding area between the two EVA plates. The laminate bond strength and maximum elongation data were analyzed by one-way ANOVA, followed by the Tukey's and the Dunnet test. The failure mode data was analyzed using the chi-square test (α = .05). RESULTS: EVA surface treatment significantly influenced the laminate bond strength and maximum elongation (p < .001). The control group had a higher contact angle and significantly lower laminate bond strength and maximum elongation than the other groups (p < .001). The acrylic resin monomer and chloroform-treated specimens had similar laminate bond strength and maximum elongation. The acrylic resin monomer group had a significantly lower contact angle (p < .001). CONCLUSIONS: All treatments had a significantly higher laminate bond strength and maximum elongation than the control group. The acrylic resin monomer and chloroform groups had a significantly higher laminate bond strength and maximum elongation and the acrylic resin monomer group had a lower contact angle than the other groups. The chloroform should be avoided due its hazardous effects.


Assuntos
Colagem Dentária , Propriedades de Superfície , Clorofórmio , Resinas Acrílicas/química , Etilenos , Teste de Materiais , Análise do Estresse Dentário
4.
J. appl. oral sci ; 31: e20230241, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1521079

RESUMO

Abstract Objective The use of a fiber glass post (FGP) type and choice of FGP diameter to restore endodontically treated incisors without ferrule is controversial. This study evaluated survival rate and failure mode of severely compromised central incisors without ferrule rehabilitated using resin-based composite (RBC) with or without FGP with different diameters. Methodology A total of 60 decoronated bovine incisors without a ferrule were endodontically treated and prepared for 1.4, 1.6, and 1.8 mm diameter FGPs (Whitepost System DC 0.5, Fit 0.4, and DCE 0.5; FGM). Half of the teeth received FGPs cemented using dual-cure resin cement (Allcem Core; FGM), the other half were filled using only bulk-fill RBC (OPUS Bulk Fill; FGM). The crowns were directly restored with RBC. The roots were embedded in polystyrene resin and the periodontal ligament was simulated with polyether impression material. Fatigue testing was conducted under 5 Hz cyclic loading at 30 degrees to the incisal edge, beginning at 50 N (5,000 cycles) as a warmup. After, the load was increased 100 N every 15,000 cycles until fracture occurred. All specimens were subjected to transillumination, micro-CT analysis, and digital radiography before and after fatigue testing. Fracture mode was classified according to severity and repair potential. Data were analyzed with Kaplan-Meier survival test and post hoc log-rank test (α=0.05) for pairwise comparisons. Results Using FGP significantly increased the number of cycles to failure, irrespective of FGP diameters (p=0.001). The FGP diameters had no statistically significant effect on cycles to failure or failure mode. Conclusion Using FGP without ferrule improved survival rate of structurally severely compromised central incisors compared with rehabilitation without FGP. The diameter of the FGPs had no effect on the survival rate and failure mode.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...